Return
Print
Email
3M™ Rejacketing Sleeve, RJS-5-10FT, 10 ft (3 m) coil, 3.3-35 kV
50f3ef508e809b4668ce3860cb938beb338503e9.jpg

3M™ Rejacketing Sleeve, RJS-5-10FT, 10 ft (3 m) coil, 3.3-35 kV

Call For Price
  • Part Number: 7000132763
  • UPC:
Quantity:
Add To Cart
Add To Estimate
Add To Wishlist
Compare Item
Product Overview
3M™ Rejacketing Sleeves RJS Series are designed so that 3M™ Cold Shrink QT-III and Q-TIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armoured and non-armoured configurations. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. The 3M™ Rejacketing Sleeve RJS-5/10 is to be used in conjunction with 3M™ Cold Shrink Breakout Boots and Silicone Rubber Terminations. 3M™ Rejacketing Sleeve RJS-5/10 has a metallic shield diameter range of 1.28-1.62 inch (32.5-41.1 mm), a voltage range of 3.3-35.0 kV, and one 10-foot (3 m) coil per case.3M Rejacketing Sleeves RJS Series are designed so that 3M Cold Shrink QT-III & Q-TIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armoured and non-armoured configurations. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. 3M Rejacketing Sleeve RJS-5/10 are designed to be used in conjunction with 3M Cold Shrink Breakout Boots and Silicone Rubber Terminations.
Specifications
Details
Industrial Category:
Electrical Supplies
Industrial Subcategory:
Plugs and Receptacles
Breakout Boot:
No
Color Family:
Gray
Dielectric Strength (V/mil):
428 V/mil
ECCN:
EAR99
Elongation:
910.0 %
Harmonized Tariff Schedule Nbr:
3926909980
Inner Diameter After Shrink (Imperial):
1.3 in
Inner Diameter After Shrink (Metric):
32.5 mm
Inner Diameter Before Shrink (Imperial):
1.62 in
Inner Diameter Before Shrink (Metric):
41.1 mm
Insulation Rejacketing:
Yes
Metallic Shield Diameter Range:
1.28 - 1.62 in
Operating Temperature (Celsius):
105
Operating Temperature (Fahrenheit):
194
Overall Length (Imperial):
10.0 ft
Overall Length (Metric):
3048.0 mm
Product Color:
Dark Grey
Product Type:
Splice Jacketing and Rejacketing Kits
RoHS EU Comments:
Contact 3M for information
Temperature Rating:
356°F (180°C) Class H
Tensile Strength (Imperial):
1058 Pound-Force Per Square
Unit of Use - Customary Height Dimension:
5.50
Unit of Use - Customary Net Weight:
1.9631
Unit of Use - Item Quantity:
1.0
Unit of Use - Item Unit:
EACH
Unit of Use - Total Unit Quantity:
1.0
Unit of Use - Unit:
EACH
Voltage Range:
3.3 - 35 kV
Other Details
Designed to be used in conjunction with 3M™ Cold Shrink Breakout Boots and 3M™ Silicone Rubber Terminations
Easy to adjust sleeve length
Excellent resistance to ozone and ultra-violet radiation
Good solvent resistance
heat or special tools required
Installs quickly and accommodates a wide range of cable sizes
No torches
Packaged as a 10-foot (3 m) coil
Seals tight and retains resiliency and pressure