3M™ Rejacketing Sleeve, RJS-2-10FT, 10 ft (3 m) coil, 3.3-15 kV
0e529822a00e1a602e5ef438bb85da6ebc2bb7ad.jpg

3M™ Rejacketing Sleeve, RJS-2-10FT, 10 ft (3 m) coil, 3.3-15 kV

Call For Price
  • Part Number: 7100005779
  • UPC:
Quantity:
Add To Cart
Add To Estimate
Add To Wishlist
Compare Item
Product Overview
3M™ Rejacketing Sleeves RJS Series are designed so that 3M™ Cold Shrink QT-III and Q-TIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armoured and non-armoured configurations. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. The 3M™ Rejacketing Sleeve RJS-2 is to be used in conjunction with 3M™ Cold Shrink Breakout Boots and Silicone Rubber Terminations. The 3M™ Rejacketing Sleeve RJS-2 has a metallic shield diameter range of 0.6-0.8 inch(15.2-20.3 mm), a voltage range of 3.3-15 kV and one 10-foot coil per case.
Specifications
Details
Industrial Category:
Electrical Supplies
Industrial Subcategory:
Plugs and Receptacles
Breakout Boot:
No
Color Family:
Gray
Dielectric Strength (V/mil):
428 V/mil
ECCN:
EAR99
Elongation:
910.0 %
Inner Diameter After Shrink (Imperial):
0.6 in
Inner Diameter After Shrink (Metric):
15.2 mm
Inner Diameter Before Shrink (Imperial):
0.8 in
Inner Diameter Before Shrink (Metric):
20.3 mm
Insulation Rejacketing:
Yes
Metallic Shield Diameter Range:
0.60 - 0.80 in
Operating Temperature (Celsius):
105
Operating Temperature (Fahrenheit):
221 Degree Fahrenheit
Overall Length (Imperial):
10.0 ft
Overall Length (Metric):
3048.0 mm
Product Color:
Dark Grey
Product Type:
Splice Jacketing and Rejacketing Kits
RoHS EU Comments:
Contact 3M for information
Temperature Rating:
356°F (180°C) Class H
Tensile Strength (Imperial):
1058 Pound-Force Per Square
Unit of Use - Customary Net Weight:
1.2131
Unit of Use - Item Quantity:
1.0
Unit of Use - Item Unit:
EACH
Unit of Use - Total Unit Quantity:
1.0
Unit of Use - Unit:
EACH
Voltage Range:
3.3 - 15 kV
Other Details
Comes in one 10-foot (3 m) coil
Designed to be used in conjunction with 3M™ Cold Shrink Breakout Boots and 3M™ Silicone Rubber Terminations
Easy to adjust sleeve length
Excellent resistance to ozone and ultra-violet radiation
Good solvent resistance
heat or special tools required
Installs quickly and accommodates a wide range of cable sizes
No torches
Seals tight and retains resiliency and pressure